IPV specification

IPV3–xx/2–A* Power supply voltage – 5V, 12В, 27В ±10%
Passband – 0 .. 2000 Hz
Range of accelerations – ±2, ±10, ±50 g,
Amplitude characteristic error– 3%
Variations in frequency response – 3 .. 10%
Output signal – 0 .. 5 V
High accuracy and stability of amplitude characteristic;
Broad passband;
Excess-voltage protection of input and output;
Output channel range is aligned with the most of DAQ.
Basic variant with analogue output. Is recommended for extreme applications.
IPV3–xx/2–AB* Power supply voltage – 5V, 12В, 27В ±10%
Passband – 0 .. 2000 Hz
Range of accelerations – ±2, ±10, ±50 g,
Amplitude characteristic error – 3%
Variations in frequency response – 3 .. 10%
Output signal – -10 .. +10 V
High accuracy and stability of amplitude characteristic;
Broad passband;
Output channel extended range.
Basic variant with analogue output modification.
Is recommended for extreme applications.
IPV3–xx/0.85–RS232* Power supply voltage – 5V, 12V, 27V ±10%
Passband – 0 .. 850 Hz
Range of accelerations – ±2, ±10, ±50 g,
Output signal – RS232
Program correction of amplitude;
Is simply connected to any computer.
Basic variant with digital output.
Is recommended for laboratory researches, rapid measurements.
IPV3–xx/2–RS485* Power supply voltage – 5V, 12В, 27V ±10%
Passband – 0 .. 2000 Hz
Range of accelerations – ±2, ±10, ±50 g,
Output signal– RS485
Program adjustment of amplitude characteristic;
Broad passband;
Possibility of data transfer at long intervals.
Basic variant with digital output modification. Is recommended for remote samples.
IPV3(2,1)–xx/2–ALE* Power supply voltage – 6.3V ±10%
Passband – 0 .. 2000 Hz
Range of accelerations – ±2, ±10, ±50 g,
Amplitude characteristic error – 7%
Variations in frequency response – 1.5 .. 5%
Output signal – 0 .. 5 V
Broad passband;
Average amplitude characteristic error;
Low nonuniformity of frequency response;
Signal range is aligned with the most of DAQ;
Cheap modification of basic variant with analogue output. Is recommended for system integration with the big amount of closely approximated measuring points.
IPV3(2,1)–xx/2–UALE* Power supply voltage – 5V ±10%
Passband – 0 .. 2000 HZ
Range of accelerations – ±2, ±10, ±50 g,
Amplitude error depends on power supply.
Variations in frequency response – 1.5 .. 5%
Output signal – 0 .. 5 V
Broad passband;
Low accuracy of amplitude characteristic error;
Low nonuniformity of frequency response;
Signal range is aligned with the most of DAQ;
Very cheap modification of basic variant with analogue output.
Is recommended for system integration with the big amount of closely approximated measuring points.